- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  
  392
Circular Chart Recorder  


Input Board
General    
Number of inputs   1, 2, 3 or 4
Input Types   dc Volts, milli-volts, Dc milli-amps (with shunt) Thermocouple, 2/3 wire RTD
  T/C Types:   B, C, E, J, K, L, N, R, S, T, Ni/NiMo
  RTD Types:   Pt100A, Pt100D, Cu10, Ni100, Ni120
  Others:   Linear, Square root, X3/2, X5/2, log User-entered.
Input Type mix     Freely Configurable
Max number of inputs     4
Input ranges     See Table 1
Termination     Terminal Block
 
Hardware Range Input Accuracy Minimum Span
4.0 to 20mV 0.02mV 4mV
12 to 60mV 0.06mV 15mV
16 to 80mV 0.08mV 20mV
40 to 200mV 0.20mV 50mV
80 to 400mV 0.40mV 100mV
0.34 to 1.7V 1.7mV 425mV
0.50 to 2.5V 2.5mV 625mV
1.00 to 5.0V 5mV 1.25V
Table 1
Shunt/Attenuator     Internally mounted resistor modules
Additional error due to shunt   0.1% of input
Additional error due to attenuator   0.2% of input
 
Recorder
Performance      
Input resolution     0.01% of operating gain span
Pen position resolution     1% of chart range
Display accuracy     ±(0.05% of operating gain span / + 0.05% of reading
Pen response     1 second to full scale
Channel update rate     250ms
CJC rejection     ±0.5% from 25°C
Noise Rejection (48 to 62Hz)    
  Common mode:   >130dB (Channel to Channel & Channel to Ground)
  Series Mode:   >60dB
Input Impedance     >20MΩ
 
Power Requirements
Line voltage ( 45- 65Hz )     90 to 132 Volts or 180 to 264 Volts (User Selectable)
Low voltage option     24V dc
      <25VA (115VA with case heater) 25W dc
Fuse     20mm Slow blow 500mA/240V ac
20mm slow blow 1A/120V ac
20mm slow blow 2A/24V dc
Recorder supply voltage (mains) fuse must not exceed 3A
 
Environmental Performance
Temperature Limits Operation:   0 to 50°C / (-20 to 50°C with heater)
  Storage:   -20 to +70°C
Humidity Limits (non - condensing)   10 to 90%
Protection Standard:   NEMA3 (IP54)
  Waterproof:   NEMA4 (IP65)
Shock     BS EN60873 and BS EN61010
Vibration (EN60873)     1g peak at 60Hz to 150Hz
Altitude (max.)     <2000 metres
 
Electromagnetic compatibility (EMC)
  Emissions:   BS EN50081-2
  Immunity:   BS EN50082-2
Electrical safety     BS EN61010
      Installation Cat. II; Pollution degree 2
 
Physical
Bezel size     360mm H x 380mm (when viewed from the front, offset 5mm right with respect to cut-out centre line)
Panel cut-out dimensions     340.5 H x 345mm W (both -0 +1 mm)
Depth behind bezel rear face   150mm
Weight     7kg (typical)
Panel Mounting     +5 to -30 degrees from vertical (+ = top over hang)
 
Printing System
Pen Type     Disposable Fibre-tipped pens giving approx. 500 meters of trace each
Chart type     Circular
Chart speeds     1 to 4096 hours / revolution.
 
Memory Protection
  Configuration:   saved in EEPROM
Active values (e.g. totalizers):   Super cap back up for 100hrs
 
Options
Serial Communications    
Type     Single asynchronous RS422
Baud rate     software selectable
 
Maths Pack
Number of Derived Variables   2
Functions     See table 2
 
Off High Peak (highest value since reset) Mass Flow (Linear)
Add (A+B) Low Peak (Lowest value since reset) F0 (Sterilization Constant)
Subtract (A-B) Log (Log to base 10) Relative Humidity
Multiply (A x B) Power (Power of 10) Zirconia Probe
Divide (A / B) Mass Flow (Square root)  
Linear (A x B + C) Polynomial (B + C x A + D x A2 + E x A3)
High Select (A>B -> A) Average (Single point, cumulative since reset)
Low Select (A>B -> B)  
Table 2
 
Customer Linearization tables
No. Of tables available     1
No. Of point pairs     11
 
Relay Outputs
Maximum number or relays   8 (two boards)
Maximum switching power*   60W
Maximum breaking current*   2 Amps within above power ratings
Maximum contact voltage*   250V ac within above power ratings
  or   30V dc within above power ratings
* With resistive loads      
 
Analogue (retransmission) Outputs
Max No. of Outputs     4 (2 boards)
Output Ranges Voltage:   0 to 5V dc, or 1 to 5V dc
  Current:   0 to 20mA, or 4 to 20mA (into 1000Ω)
 
Event Inputs
Max No. of inputs     16 (2 boards)
 
Transmitter Power Supply
Supply     4 Isolated 28V dc, 24mA supplies 115V ac Supply – 100mA/250V T (slow blow)
      240V ac Supply – 63mA/250V T (slow blow)
 
Controllers
Number     2
Type     Single or Dual output, 3-mode PID controllers, set-point generators and remote/local set-point switching
Last Updated Monday, July 10, 2006