Environmental performance |
|
|
| Temperature limits |
Operation: |
|
0 to 50°C |
| |
Storage: |
|
–20 to + 70°C |
| Humidity limits |
Operation/Storage: |
|
5% to 95% RH (non condensing) |
| Protection |
|
|
IP20 |
| Shock |
|
|
BS EN61010 |
|
Vibration (BS EN60068-2-6 Test Fc) |
|
2g peak |
| Altitude |
|
|
< 2000 meters |
|
|
Clock (RTC) data |
|
|
| Temperature
stability |
|
|
| |
0 to 40°C |
|
–3 to +2 ppm |
| |
–40 to +85°C |
|
±7.5 ppm |
| Ageing |
|
|
±1 ppm per year |
|
|
Electromagnetic compatibility (EMC) |
| Emissions and
immunity |
|
BS EN61326 |
|
|
Electrical Safety |
|
|
| (BS EN61010) |
|
|
Installation category II; Pollution degree 2 |
|
|
Physical |
|
|
|
| Mounting method |
|
|
DIN rail (T35) or wall mounted. |
| Mounting angle |
|
|
Connectors to be horizontal for T/C
inputs - otherwise no constraints. |
| Weight |
|
|
< 1.5kg |
|
|
Operator interface |
|
|
| Full operation,
configuration and file transfer from remote PC |
|
|
Power requirements |
|
|
| Supply voltage |
|
|
18 to 30V dc |
|
Maximum power drain |
|
10 Watts |
| Inrush current
(maximum) |
|
18 Amps |
| |
|
|
Eurotherm Model 5000P can
be used |
|
|
Back-up Battery |
|
|
| Type |
|
|
Poly-carbonmonofluoride/lithium
(BR2330) Part No. PA261095 |
| Support time (RTC) |
|
|
1 year min. with recorder unpowered |
| Replacement period |
|
|
3 years |
| Stored data |
|
|
Time; date; values for totalisers, counters
and timers; batch data; Fvalue,
Rolling average, Stopwatch etc. |
|
|
Update/archive rates |
|
|
| Input/relay output
sample rate |
|
8Hz (all channels) |
| Display update |
|
|
Network dependent |
| Sample value |
|
|
Value at sample time |
| Trend value |
|
|
Latest value at display update time |
| Calculations |
|
|
8Hz update of all alarm setpoints, maths, totaliser, counter etc. values |
|
|
Inputs |
|
|
|
|
General |
|
|
|
| Input types |
|
|
dc Volts, dc millivolts, |
| |
|
|
dc milliamps (needs external shunt) |
| |
|
|
Thermocouple, 2/3 wire RTD,
Contact closure (not ch1 or 7) |
| |
|
|
>60msec |
| Input type mix |
|
|
Freely configurable |
|
Maximum number of inputs |
|
12 |
| A/D conversion
method |
|
>16 bits, 2nd order delta-sigma |
| Termination |
|
|
Edge connector / Terminal
block |
| Noise rejection |
Common mode: |
|
>140dB (channel-to-channel) |
| |
|
|
>140dB (channel-to-ground) |
| |
Series mode: |
|
>60dB |
|
Maximum common mode voltage |
|
250 Volts continuous |
| Maximum series mode
voltage |
|
45mV at lowest (38mV) range |
| |
|
|
12 Volts at highest (10V)
range |
| Isolation* |
Channel-to-channel: |
|
300V RMS or dc (double insulation) |
|
Channel-to-common electronics: |
|
300V RMS or dc (double
insulation) |
| |
Channel-to-ground: |
|
300V RMS or dc (basic insulation) |
|
Dielectric strength (BS EN61010) |
|
(1 minute type tests) |
| |
Channel-to-channel: |
|
2500 Volts ac |
| |
Channel-to-ground: |
|
1500 Volts ac |
| Insulation
resistance |
|
>10MΩ at 500 Volts dc |
| Input
impedance |
10 Volt range: |
|
68.8kΩ |
| |
All other ranges: |
|
>10MΩ |
|
Overvoltage protection |
|
50V peak (150V peak with
attenuator) |
| Open circuit |
|
|
Recognition time: 500 msec |
| Current: |
|
|
57nA |
| Minimum break
resistance: |
|
10MΩ |
|
|
DC input ranges |
|
|
| Shunt type |
|
|
Externally mounted resistor modules |
| Additional error
due to shunt |
|
0.1% of input |
| Additional error
due to attenuator |
|
0.2% of input |
|
|
| Low Range |
High Range |
Resolution |
Maximum error
(Instrument at 20°C) |
Worst case
temperature performance |
| –38mV |
38mV |
1.4μV |
0.085% input +
0.051% range |
80ppm of input
per °C |
| –150mV |
150mV |
5.5μV |
0.084% input + 0.038% range |
80ppm of input per °C |
| –1V |
1V |
37μV |
0.084% input +
0.029% range |
80ppm of input
per °C |
| –10V |
10V |
370μV |
0.275% input + 0.030% range |
272ppm of input per °C |
|
|
DC ranges and performance |
|
|
Thermocouple data |
|
|
| Temperature scale |
|
|
ITS90 |
| Bias current |
|
|
0.05nA |
| Cold junction |
Types: |
|
Off, internal, external, remote |
|
Error: |
|
1°C max. with instrument at 25°C |
|
Rejection ratio: |
|
50:1 minimum |
|
Upscale/downscale drive |
|
High, low or none selectable for
each
thermocouple channel |
| |
Additional error |
|
0.01°C (typ.) if High/low selected |
| |
|
T/C Type |
Overall range (°C) |
Standard |
Max linearization error |
| B |
0to
+1820 |
IEC
584.1 |
0 to 400°C=1.7°C
400 to 1820°C=0.03°C |
| C |
0to +2300 |
Hoskins |
0.12°C |
| D |
0to +2495 |
Hoskins |
0.08°C |
| E |
–270 to +1000 |
IEC 584.1 |
0.03°C |
| G2 |
0 to +2315 |
Hoskins |
0.07°C |
| J |
–210 to +1200 |
IEC 584.1 |
0.02°C |
| K |
–270 to +1372 |
IEC 584.1 |
0.04°C |
| L |
–200 to +900 |
DIN43700:1985 (To
IPTS68) |
0.20°C |
| N |
–270 to +1300 |
IEC 584.1 |
0.04°C |
| R |
–50 to +1768 |
IEC 584.1 |
0.04°C |
| S |
–50 to +1768 |
IEC 584.1 |
0.04°C |
| T |
–270 to +400 |
IEC 584.1 |
0.02°C |
| U |
–200 to +600 |
DIN43700:1985 |
0.04°C |
| NiMoNiCo |
–50 to +1410 |
ASTM E1751-95 |
0.06°C |
| NiNiMo |
0 to +1406 |
Ipsen |
0.14°C |
| Platinel |
0 to +1370 |
Engelhard |
0.02°C |
| Pt20%Rh /Pt40%Rh |
0 to +1888 |
ASTM E1751-95 |
0.07°C |
|
|
Thermocouple types and ranges |
|
|
Resistance inputs |
|
|
| Temperature scale |
|
|
ITS90 |
|
Influence of lead resistance |
|
|
| |
Error: |
|
Negligible |
| |
Mismatch: |
|
1Ω/Ω |
| |
|
|
|
| Low Range |
High Range |
Resolution |
Maximum error
(Instrument at 20°C) |
Worst case
temperature performance |
| 0Ω |
150Ω |
5mΩ |
0.045% input +
0.110% range |
35ppm of input
per °C |
| 0Ω |
600Ω |
22mΩ |
0.045% input + 0.065% range |
35ppm of input per °C |
| 0Ω |
6000Ω |
148mΩ |
0.049% input +
0.035% range |
35ppm of input
per °C |
|
|
Resistance ranges – accuracy and resolution |
| |
|
|
|
|
RTD Type |
Overall range (°C) |
Standard |
Max linearization error (4102C, 4102M only) |
| Cu10 |
–20 to +400 |
General Electric
Co. |
0.02°C |
| Cu53 |
–70 to +200 |
RC21-4-1966 |
<0.01°C |
| JPT100 |
–220 to +630 |
JIS C 1604:1989 |
0 01°C |
| Ni1000 |
–60 to +250 |
DIN43760:1987 |
0.01°C |
| Ni120 |
–50 to +170 |
DIN43760:1987 |
0.01°C |
| Pt100 |
–200 to +850 |
IEC 751 |
0.01°C |
| Pt100A |
–200 to +600 |
Eurotherm
Recorders SA |
0.09°C |
| Pt1000 |
–200 to +850 |
IEC 751 |
0.01°C |
|
|
Resistance thermometer types and ranges |
|
|
Relay Outputs |
|
|
|
| Number of relays
fitted |
|
|
| |
Standard: |
|
1 |
| |
Optional: |
|
Up to 2 boards, each with 3 relays |
| Termination |
|
|
Edge connector / Terminal
block |
| Maximum ac
switching power* |
|
500VA |
|
Maximum ac breaking current* |
|
2A within above power
ratings |
| Maximum ac contact
voltage* |
|
250V within above power ratings |
| Isolation† |
Relay-to-relay: |
|
300V RMS or dc (double
insulation) |
| |
Relay-to-ground: |
|
300V RMS or dc (basic insulation) |
|
* With resistive loads. With inductive loads, derate
according to Graph 1, in which: |
| Contact life =
resistive life x F1 or F2 where |
|
F1 = measured on representative examples and |
| F2 = typical
values according to experience |
| |
|
|
|
 |
|
|
Event Input |
|
|
|
| Number of inputs |
|
|
6 discrete inputs |
| Maximum No. of
boards |
|
2 |
| Isolation |
Event input to ground: |
|
100V RMS or dc (double insulation) |
|
Event input to Event input: |
|
0V |
| Recognition levels |
Low: |
|
–30V to +0.8V |
| |
High: |
|
2 to 30V |
| Maximum frequency |
|
8Hz |
| Minimum pulse width |
|
62.5ms |
| Contact resistance |
Event: |
|
Active if resistance <35KΩ
Inactive if resistance >200KΩ
Status not defined if
35KΩ < resistance <200KΩ between
input terminal and ‘C’ terminal |
|
|
Serial Communications |
|
|
| (Typical
applications: Input of ASCII string inputs from Bar-code
readers, credit
card readers, Modbus etc.) |
|
|
ASCII Printer |
|
|
|
| ASCII Printer
support |
|
|
|
|
Isolation† |
|
|
|
| Terminals to
ground: |
|
100V RMS or dc (basic insulation) |
| †
All isolation figures are: |
|
|
| DC to 65Hz; BS
EN61010 Installation category II; Pollution degree 2: |
|
|
Transmission standard |
| EIA232 or EIA485 |