- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  
The 4100G is Obsolete and is no longer available.
Service is available on these recorders. Call Eurotherm Repairs at 703.443.0000
Please see the 5000 Series Graphic Data Acquisition recorders as replacement recorders for the 4100G.

4100G
12-channel video graphic recorder
  • Web and Ethernet Enabled
  • 12-channel graphic recorder
  • Large data archiving capability with integral PC card, floppy disk or hard disk
  • Ethernet connectivity
  • Web-browser enabled
  • E-mail alarm notification
  • High quality color display
  • 3 Mb trend history
  • Configuration/operation via touch screen or via local or remote PC
  • Math functions, timers, counters and totalizers
  • MODBUS®/Profibus communications
  • Remote file transfer
  • Relay outputs
  • Analog retransmission output
  • Nuclear certified models available through Wyle Labs
Support Library

The 4100G is a high specification graphic recorder capable of plotting up to 12 input signals, math (derived) channels, totalizer values etc. Enclosed in a sheet steel case designed to meet the requirements of an industrial environment, this recorder is ideal for continuous and batch processes as well as test and QA environments.

Display
The display consists of a 5.5” TFT color LCD originally designed for the harsh environment of automotive applications. This display is overlaid with a tough touch-screen membrane and the whole fascia can be sealed to IP65. The display can show process values as if traced on a traditional chart, as bargraphs or in numeric format. Process alarms can also be viewed in a tabulated display and can be filtered by group or point.

Configuration
The recorder is fully configurable from the touch-screen using a simple menu system with text prompts. This allows access both to simple operator facilities and, via a password, to the input and instrument configuration.

The recorder can also be configured from a software package, allowing the user to set up the configuration off-site for later downloading to the recorder.


Features and Options
NUMBER OF INPUT CHANNELS
No Channels (for communications input)
2 channels
3 Channels
4 Channels
6 Channels
8 Channels
9 Channels
10 Channels
12 Channels
TREND HISTORY MEMORY
3Mb Memory
POWER SUPPLY
90-264V ac, 45-65Hz
24-48Vdc, ac 45-400Hz
ARCHIVE TYPE
1.44Mb floppy disk drive P
C memory card (PCMCIA) drive
ARCHIVE LOCK
DIN archive access lock
IP65 panel protection & archive lock
Archive lock & dust protection
Chassis lock
Archive lock & chassis lock
IP65 to panel, archive & chassis locks
Dust protection, archive & chassis locks
APPROVALS
Seismic (IEEE344:1987-inc lock)
OPERATING LANGUAGE
English
French
German
MANUAL LANGUAGE
English
French
German
24V TRANSMITTER POWER SUPPLY
120V 3 channel TPS
240V 3 channel TPS
120V 6 channel TPS
240V 6 channel TPS
CERTIFICATION
CuL
CE
PORTABLE KITS
RELAYS CLOSED IN ALARM
4 normally closed relay o/p 8 normally closed relay o/p
12 normally closed relay o/p
16 normally closed relay o/p
RELAYS OPEN IN ALARM
4 normally open relay o/p
8 normally open relay o/p
2 normally open relay o/p
16 normally open relay o/p
FORM C RELAYS
3 form C relay o/p
6 form C relay o/p
9 form C relay o/p
12 form C relay o/p
ANALOG RETRANSMISSION
2 retransmission channels
4 retransmission channels
EVENT INPUTS
6 events inputs
ARCHIVING FORMAT
ASCII logging
Configuration save & restore
Packed logging, incl. PC sw to unpack data

MEMORY CARD SIZE
PCMCIA (Type II)

8Mb Flash ATA Card
16Mb Flash ATA Card
32Mb Flash ATA Card
64Mb Flash ATA Card
256Mb Flash ATA Card

COMMUNICATIONS
RS 485 Modbus RTU
RS 232 Modbus RTU
RS 232 File Transfer
Profibus DP (includes GSD editor)
RS485 + File Transfer
MATHEMATICAL CAPABILITIES
Level 1 (basic functions), 24 derived variables
Level 2 (advanced functions), 24 derived variables
Level 3, level 2 plus exponential display
TOTALIZERS, TIMERS & COUNTERS
2, 4 or 6 totalizers
6 timers & 6 counters
6 totalizers, 6 timers & 6 counters
CUSTOM LINEARIZATION TABLE
32 point curve
AC MONITOR KIT INPUTS
3 current inputs
1 voltage input
1 voltage & 1 current input
1 voltage & 3 current inputs
3 voltage inputs
3 voltage & 3 current inputs
AC MONITOR KIT VOLTAGE INPUT RANGE
0 - 300V ac, 45-65Hz
0 - 500V ac, 45-65Hz AC
MONITOR KIT CURRENT INPUT RANGE
0 - 25A ac, 45-65Hz
0 - 100A ac, 45-65Hz
0 - 1000A ac, switchable to 250A, 500A & 1000A ac, 45-65Hz1000A ac, 45-65Hz
INPUT SIGNAL CONDITIONING
250 ohm shunt resistor
100 ohm shunt resistor
100:1 attenuator
Ethernet & Web-Enabled DAQ

Chessell's tried and tested 100mm graphic recorder is now web-enabled. Improvements to the 4100G have led to a browser-enabled unit, giving you the freedom to browse your process over the Internet.

Click here to view/download the Options User Guide

This new feature allows real-time information to be monitored from an Internet-enabled PC, anywhere in the world. The 4100G connects to the world wide web via an Ethernet network. Use of an embedded TCP/IP server on the 4100G means that real-time process data can be browsed on a PC that has no specialized data acquisition software installed - only a standard Internet browser is required.

Data is displayed in the form of a chart, bar graphs and alarm-summary, incorporated into a single screen, displaying all pertinent process information concurrently. The data can be logged to the network via the client PC.

The web-enabled unit also features e-mail alarm notification. For user-selected alarms, a message is sent to a stored list of e-mail addresses. Message content includes unit identification tag, channel tag, alarm number and the time at which the alarm went active.

Nuclear Certified Recorders

It is necessary to meet very stringent testing and qualifications standards to provide recorders and data acquisition units to the nuclear power industry. Recorders that are used in this sector typically have to meet the following qualifications:

  • IEEE 344 specifications for use in Class 1E applications.
  • EPRI Specification TR-102323 for EMI and RFI
  • Software V&V Per IEEE Standard 7-4.3.2-1993 for software verification and validation.
  • 10CFR50 Appendix B requirements and Part 21 for complete assurance and compliance for safety related applications.
  • The software and the firmware are frozen for the recorders that are supplied by Wyle Laboratories. Chessell has committed to the long-term availability of these frozen versions.

Wyle Labs, an independent testing laboratory and sales organization, provides all the necessary documentation and support for the use of Chessell recorders in the nuclear power sector. Your regional Chessell representative will work with Wyle Labs towards the certification of recorders for your application.

Last updated December 3, 2003