- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  
5100E
Technical Specifications

TECHNICAL SPECIFICATION (Recorder)
Standard features
Inputs Six universal input channels
Outputs One form C relay
Archiving Onto 3.5 inch floppy disk
Communications standard Ethernet

Environmental Performance
Temperature limits Operation: 5 to 40°C; Storage: -20 to + 50°C
Humidity limits Operation/Storage: 20% to 80% RH(non-condensing)
Protection Bezel and display IP65
Sleeve: IP20
Shock BS EN61010
Vibration (10 to 150 Hz) 2g peak
Altitude <2000 metres.

Electromagnetic compatibility (EMC)
Emissions and immunity BS EN61326

Electrical saftey
(BS EN61010) Installation cat. II; Pollution degree 2

Physical
Panel mounting DIN43700
Bezel size 5.67" x 5.67" (144mm x 144mm)
Panel cutout dimensions 5.43" x 5.43"[(138x138) - (both – 0 + 1 mm)]
Depth behind bezel rear face
With terminal cover: 9.76" (248mm)
Without terminal cover: 8.39" (213mm)
Weight 1.36 lb (3kg) max
Panel mounting angle up to +15° from vertical

Operator interface
Type Color STN LCD with cold cathode backlighting
Fitted with resistive, analog, toughened touch-panel
Size and resolution 1/4VGA (320 x 240 pixels)

Power requirements
Line voltage 47 to 63 Hz 85 to 265V
Power (Max) 60VA (Inrush current 36A)
Fuse type None
Interrput protection Holdup >200ms at 240V ac, with full load

Back-up battery
Type Poly-carbonmonofluoride/lithium (BR2330)
Support time A fully charged new battery supports the real-time clock for a minimum of 1 year with the recorder unpowered
Replacement period 3 Years

Ethernet communications
Electrical standard 10Mbs Ethernet. 10BaseT.
Transport protocol TCP/IP. Provision for File Transfer Protocol (FTP)

Technical Specification (Input board)
General
Input types dc Volts, dc millivolts,
dc milliamps (with shunt),
Thermocouple,
2/3 - wire RTD
Contact closure (not chan. 1) >60ms
Input type mix Freely configurable.
Maximum number of inputs 6
Termination Edge connector / terminal block
Noise rejection (48 to 62 Hz) Common mode: >140dB (channel to channel and channel to ground
Series mode: >60dB.
Maximum common mode voltage 250 Volts continuous
Maximum series mode voltage 45 mV at lowest range;
12 Volts peak at highest range.
Insolation Channel to channel: 300V RMS or dc (double insulation)
Channel to common electronics: 300V RMS or dc (double insulation)
Channel to ground: 300V RMS or dc (basic insulation)
Dielectric strength (BS EN61010) (1 minute type tests)
Channel to channel 2300 Vac
Channel to ground 1350 Vac
Insulation resistance >10MW at 500 V dc
Input impedance 38mV, 150 mV, 1 V ranges: >10MW;
10V range: 68.8 kW
Over voltage protection 50 Volts peak (150V with attenuator)
Open cirucit detection +57 nA max.
Recognition time 500 msec
Minimum break resistance 10 MW

Update/archive rates
Input/Relay-output sample rate 8 Hz
Display update 1 Hz
Archive sample-value Latest value at archive time
Trend/Display value Latest value at display update time

DC Input ranges
Shunt Externally mounted resistor modules
Additional error due to shunt 0.1% of input
Additional error due to attenuator 0.2% of input
Performance See table 1
Low
Range
High
Range
Resolution Maximum Error
(Instrument at 20°C)
Worst case temperature
performance
38 mV -38 mV 1.4mV 0.085% input + 0.051% range 80ppm of input der deg C
150 mV -150 mV 5.5mV 0.084% input + 0.038% range 80ppm of input per deg C
1 Volt -1 Volt 37mV 0.084% input + 0.029% range 80ppm of input per deg C
10 Volts -10 Volts 370mV 0.275% input + 0.030% range 272ppm of input per deg C
Table 1 DC performance

Thermocouple data
Temperature scale ITS 90
Bias current 0.05 nA
Cold junction types Off, internal, external
CJ error 1°C max with inst. at 25°C
CJ rejection ratio 50:1 minimum
Remote CJ Via any user-defined channel
Upscale / downscale drive High, low or none selectable for each
thermocouple channell
Types and ranges See table 2
T/C Type Overall range (°C) Standard Maximum linearisation
error
B 0 to + 1820 IEC584.1 0 to 400°C: 1.7°C
400 to 1820°C: 0.03°C
C 0 to + 2300 Hoskins 0.12°C
D 0 to 2495 Hoskins 0.08°C
E -270 to + 1000 IEC584.1 0.03°C
G2 -0 to 2315 Hoskins 0.07°C
J -210 to + 1200 IEC584.1 0.02°C
K -270 to + 1372 IEC584.1 0.04°C
L -200 to + 900 DIN43700:1985
(To IPTS68)
0.20°C
N 270 to + 1300 IEC584.1 0.04°C
R -50 to + 1768 IEC584.1 0.04°C
S -50 to + 1768 IEC584.1 0.04°C
T -270 to + 400 IEC584.1 0.02°C
U -200 to + 600 DIN43710:1985 0.08°C
NiMoNiCo 0 to + 1406 Ipsen 0.14°C
Platinel 0 to + 1370 Engelhard 0.02°C
Table 2 Thermocouple types and ranges

Resistance inputs
Ranges (including lead resistance) 0to 150W, 0 to 600W, 0 to 6kW
Influence of lead resistance Error=negligible;
Mismatch=1W/W
Temperature Scale ITS90
Accuracy and resolution See table 3
Low
Range
High
Range
Resolution Maximum error
(Instrument at 20°C)
Worst case temperature
performance
0W 150W 5mW 0.045% input + 0.110% range 35ppm of input per deg C
0W 600W 22mW 0.045% input + 0.065% range 35ppm of input per deg C
0W 6kW 148mW 0.049% input + 0.035% range 35ppm of input per deg C
Table 3 Resistance ranges - accuracy and resolution

RTD Type Overall range (°C) Standard Max linearisation error
Cu10 -20 to + 400 General Electric Co. 0.02°C
JPT100 -220 to + 630 JIS C1604:1989 0.01°C
Ni100 -60 to + 250 DIN43760:1987 0.01°C
Ni120 -50 to + 170 DIN43760:1987 0.01°C
Pt100 -200 to + 850 IEC 751 0.01°C
Pt100A -200 to + 600 Eurotherm Recorders SA 0.09°C
Pt1000 -200 to + 850 IEC 751 0.01°C
Table 4 RTD types and ranges

Relay outputs
Termination 3-way connector
Maximum switching power* 500VA or 60W
Maximum breaking current* 2 Amps within above power ratings
Maximum contact voltage* 250V within above power ratings
Isolation Contact to contact: 300V RMS or dc (double insulation)
Contact to ground: 300V RMS or dc (basic insulation)
Estimated life* 30,000,000 operations
Last Updated Friday, May 12, 2006