| 4102C |
|
|
| 100mm Strip Chart Recorder |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
![]() |
|
|
The 4102C is a low cost, 100mm strip chart recorders, providing recording for up to 4 (continuous pen) or 6 (multi-point) process variables. Designed to fit a standard DIN panel cut out (138 x 138 mm), these recorders feature an exceptionally small back panel dimension of 236mm with the cover fitted, that makes them ideal for installations where space is at a premium. Display |
|||
|
Configuration Modular Design |
||||
| |
||||
Sterilizer Option 4102 Contact 1: When closed the chart runs normally. When open the pens are parked at Zero and the chart winds on 80mm. Contact 2: Applies to annotating recorders only. When closed the current time and date is printed, and as long as the contact remains closed the chart will run at its selected speed, with annotation inhibited. Once the contact goes open the pens are zeroed; the time date, scales and chart speed are printed and the chart is advanced by 80mm and stopped. Contact 3: Applies to annotating recorders only. On closure the message “EVENT START HH:MM:SS” is printed, where HH:MM:SS show the time of closure in hours, minutes and seconds. On the contact opening, the message “DURATION HH:MM:SS” is printed, where HH:MM:SS shows how long the contact was closed, therefore providing Sterilization time. Contact 4: If either contact 1 or 2 is closed then pen 4 (continuous) or pen 6 (multipoint ) is used to show the status of Contact 4. Whilst contact 4 is open the trace is at 100%, whilst closed the trace is at 96%. |
||||
|
||||
| Last Updated Friday, July 21, 2006 |