| Input Board |
| General |
|
|
| Input types |
|
dc Volts, dc millivolts,dc milliamps (with shunt), Thermocouple, 2 / 3-wire RTD
(Channel 1 can be RTD only if no other channels are thermocouple) |
| Input type mix |
|
User configurable |
| Max no of inputs |
|
|
6 |
| Input ranges |
|
|
–30 to +150mV; –0.2 to +1 Volt; –2 to +10 Volts |
| Termination |
|
|
Edge connector / terminal block |
| Noise rejection (48 to 62 Hz) |
|
|
| |
Common mode: |
|
>140dB (channel to channel and channel to ground). |
| |
Series mode: |
|
>60dB. |
| Maximum common mode voltage |
|
250 Volts continuous |
| Maximum series mode voltage |
|
180 mV at lowest range; 12 Volts peak at highest range. |
| Isolation (dc to 65 Hz; EN61010) |
|
Installation cat. II; Pollution deg. 2 |
| Channel to channel: |
|
300V RMS or dc (double insulation) |
| Channel to common electronics: |
|
300V RMS or dc (double insulation) |
| Channel to ground: |
|
300V RMS or dc (basic insulation) |
| Dielectric strength (BS EN61010) |
|
(1 minute type tests.) |
| Channel to channel: |
|
2300 Vac |
| Channel to ground: |
|
1350 Vac |
| Insulation resistance |
|
|
>10MΩ at 500V dc |
| Input impedance |
|
|
150mV and 1V ranges: >10MΩ; 10V range: 68.8kΩ |
| Over voltage protection |
|
|
50 Volts peak (150V with attenuator) |
| Open circuit detection |
|
|
±57nA max. |
| Recognition time |
|
|
500 msec |
| Minimum break resistance |
|
10MΩ |
| |
| DC Input ranges |
| Shunt/attenuator |
|
|
Externally mounted resistor modules |
| Additional error due to shunt |
|
0.1% of input |
| Additional error due to attenuator |
|
0.2% of input |
| Performance |
|
|
See table 1 |
| |
| Low Range |
High Range |
Resolution |
Maximum error (Instrument at 20°C) |
Worst case temperature performance |
–30mV –0.2V –2V |
150mV 1V 10V |
5.5μV 37μV 370μV |
0.084% input + 0.053% range 0.084% input + 0.037% range 0.275% input + 0.040% range |
80ppm of input per °C 80ppm of input per °C 272ppm of input per °C |
|
|
Table 1 DC performance |
| |
| Thermocouple data |
| Temperature scale |
|
|
ITS 90 |
| Bias current |
|
|
0.05 nA |
| Cold junction types |
|
|
Off, internal, external |
| CJ error |
|
|
1°C; instrument at 25°C |
| CJ rejection ratio |
|
|
50:1 minimum |
| Upscale / downscale drive |
|
|
High, low or none |
| Types and ranges |
|
|
See table 2 |
| |
| T/C Type |
Overall range (°C) |
Standard |
Max
linearization error |
| B |
0 to +1820 |
IEC 584.1 |
0 to 400°C: 1.7°C 400 to 1820°C:0.03°C |
C D E G2 J K L |
0 to +2300 0 to +2495 –270 to +1000 0 to +2315 –210 to +1200 –270 to +1372 –200 to +900 |
Hoskins Hoskins IEC 584.1 Hoskins IEC 584.1 IEC 584.1 DIN43700:1985 (To IPTS68) |
0.12°C 0.08°C 0.03°C 0.07°C 0.02°C 0.04°C 0.20°C |
N R S T U Ni/NiMo Platinel |
–270 to +1300 –50 to +1768 –50 to +1768 –270 to +400 –200 to +600 0 to +1406 0 to +1370 |
IEC 584.1 IEC 584.1 IEC 584.1 IEC 584.1 DIN43700:1985 Ipsen Englehard |
0.04°C 0.04°C 0.04°C 0.02°C 0.08°C 0.14°C 0.02°C |
|
|
Table 2 Thermocouple types and ranges |
| |
| Resistance inputs |
| Ranges (including lead resistance) |
|
0 to 600Ω, 0 to 6kΩ |
| Influence of lead resistance |
|
Error: negligible; Mismatch: 1 Ω/Ω |
| Temperature scale |
|
|
ITS90 |
| Resolution and performance |
|
See Table 3 |
| RTD types and ranges |
|
|
See Table 4 |
| |
| Low Range |
High Range |
Resolution |
Maximum error (Instrument at 20°C) |
Worst case temperature performance |
0Ω 0Ω |
600Ω 6000Ω |
22mΩ 148mΩ |
0.045% input + 0.065% range 0.049% input + 0.035% range |
35ppm of input per °C 35ppm of input per °C |
|
|
Table 3 Resolution and performance for resistance inputs |
| |
| RTD Type |
Overall range (°C) |
Standard |
Max
linearization error |
JPT100 Ni1000 Ni120 Pt100 Pt100A Pt1000 |
–220 to +630 –60 to +250 –50 to +170 –200 to +850 –200 to +600 –200 to +850 |
JIS C 1604:1989 DIN43760:1987 DIN43760:1987 IEC 751 Eurotherm Recorders SA IEC 751 |
0.01°C 0.01°C 0.01°C 0.01°C 0.09°C 0.01°C |
|
|
Table 4 RTD types and ranges |
| |
| Recorder |
| Board types |
Standard: |
|
Universal input / control board |
| |
Options: |
|
3- Change-over relay output board
Transmitter power supply
Event input board, Annotator board |
| |
|
|
|
| |
| Environmental Performance |
| Temperature limits |
Operation: |
|
0 to 50°C. |
| |
Storage: |
|
–20 to + 70°C |
| Humidity limits |
Operation: |
|
5% to 80% RH |
| (non-condensing) |
Storage: |
|
5% to 90% RH |
| Protection |
Door and Bezel: |
|
IP54 |
| |
Sleeve: |
|
IP20 |
| Transmitter PSU cover: |
|
IP10 |
| Shock |
|
|
BS EN61010 |
| Vibration |
|
|
2g peak at 10 Hz to 150Hz |
| Altitude (max.) |
|
|
2000 meters |
| |
| Power requirements |
| Line voltage |
Standard: |
|
90 to 264V at 45 to 65 Hz |
| Enhanced interrupt protection: |
|
90 to 132V at 45 to 65 Hz |
| |
Low voltage: |
|
20 to 54V dc or 20 to 35V ac (45 to 400 Hz) |
| Power (Max) |
|
|
100 VA |
| Fuse type |
|
|
Not user accessible |
| Interrupt protection |
Standard: |
|
40ms at 75% max. instrument load |
| |
Enhanced: |
|
120ms at 75% max. instrument load |
| |
| Electromagnetic compatibility (EMC) |
| |
Emissions |
|
BS EN50081-2 |
| |
Immunity |
|
BS EN50082-2 |
| Electrical safety |
|
|
To EN61010: Installation category II; Pollution degree 2 |
| |
| Physical |
| Panel mounting |
|
|
DIN43700 |
| Bezel size |
|
|
144 x 144 mm. |
| Panel cutout dimensions |
|
|
138 x 138 (both - 0 + 1 mm) |
| Depth behind bezel rear face |
|
220 mm (No terminal cover);
236 mm (standard terminal cover)
275 mm (long terminal cover closed)
390mm (long terminal cover open) |
| Weight |
|
|
< 3.5kg |
| Panel mounting |
|
|
Vertical ±30°C |
| |
| Printing System |
| Pen type |
|
|
Six nib cartridge |
| Pen resolution |
|
|
0.2 mm |
| Trace colors |
|
|
See Table 6 |
| Pen life |
|
|
1.5 x 106 dots per color |
| Update rate |
|
|
2 Hz |
| Response time (max) |
|
|
1 pass every 5 seconds |
| Characters per line |
|
|
42 |
| |
| Channel |
1 |
2 |
3 |
4 |
5 |
6 |
| Color |
violet |
red |
black |
green |
blue |
brown |
|
|
Table 6 4101M, 4102M Trace colors |
| |
| Paper transport |
| Type |
|
|
Stepper motor driving sprocket tube |
| Chart speeds |
|
|
Off, 5, 10, 20, 30, 60, 120 mm/hr |
| Chart type |
Standard |
|
16 meter z-fold |
| |
Option |
|
32 meter roll |
| |
| Vacuum florescent display |
| Process value with Channel number |
|
Four, blue 15mm high characters minus sign as required Single, green 8mm high character |
| Alarm indication |
|
|
Pair of red arrows for high and low alarms |
| Channel hold indication |
|
|
Red ‘H’ below channel number when channel hold in operation |
| Keypad; |
|
|
5-key keypad for operator / configuration access |
| |
| Options |
| All isolation figures are Installation category II and
Pollution degree 2 |
| |
| Relay outputs |
| Maximum switching power |
|
500VA |
| Maximum breaking current |
|
2 Amps within above power ratings |
| Maximum contact voltage |
|
|
250V within above power ratings |
| Maximum dc ratings |
|
|
See Graph 2 |
| Isolation (dc to 65Hz; BS EN61010) |
|
|
| |
Contact-contact |
|
300V RMS or dc (double insulation) |
| Contact to ground |
|
300V RMS or dc (basic insulation) |
| Estimated life* |
|
|
30,000,000 operations |
| * With resistive loads. With inductive loads, derate according to Graph 1, in which: |
Contact life = resistive life x F1 or F2 where
F1 = measured on representative examples and
F2 = typical values according to experience |
| |
 |
| |
| Event inputs |
| Isolation (dc to 65Hz; BS EN61010) |
|
|
| Event input to ground: |
|
100V RMS or dc (double insulation) |
| Event input to Event input: |
|
0V |
| Recognition levels |
Low: |
|
–30V to +0.8V |
| |
High: |
|
2 to 30V |
| |
| Transmitter Power Supply |
| Output voltage |
|
|
3 or 6 x 25V dc (nom) outputs |
| Isolation (dc to 65Hz; BS EN61010) |
|
|
| Channel to channel: |
|
100V RMS or dc (double insulation) |
| Channel to ground: |
|
100V RMS or dc (basic insulation) |
| Cover rating |
|
|
IP10 |